MCS 620T
podhledový reproduktor evakuační
6 W / 100 V, 92 dB, 150 – 20 000 Hz, 6,5″ fullrange speaker, ABS plastic, EN 54–24 certified
Suitable for: wall installation in the interior, for sounding comercial places, offices, administrative places, passages and hotels, for evacuation system
30 W / 100 V, 8 Ω, 89 dB, 80 – 20 000 Hz, handle, 5″ woofer, dome tweeter, non-fire plastic, EN 54–24 certified
Suitable for: wall installation in the interior, for sounding comercial places, restaurnts, bars, offices, administrative places, hotels, evacuation system
30 W / 100 V, 8 Ω, 89 dB, 80 – 20 000 Hz, handle, 5″ woofer, dome tweeter, non-fire plastic, EN 54–24 certified
Suitable for: wall installation in the interior, for sounding comercial places, restaurnts, bars, offices, administrative places, hotels, evacuation system
15 W / 100 V, 92 dB, 120 – 20 000 Hz, non-fire plastic, white, also using as hang speaker, EN 54–24 certified
Suitable for: sounding passages, warehouses, protected exterior, supermarkets, evacuation system
10 W / 100 V, 150 – 15 000 Hz, 92 dB, dia. 194×170 mm, ČSN EN 60 849
Suitable for: hanging sounding, supermarkets, warehouses, production, emergency evacuation sound system
20 W / 100 V, 80 – 18 000 Hz, 92 dB, according to EN 60 849 – evacuation sound system, wide polar pattern, dia. 254
Suitable for: hanging sounding, supermarkets, warehouses, production, emergency evacuation sound system
metal, 6 W / 100 V, 91 dB, 90 – 16 000 Hz, Ø 200 mm, clamps mounting, incl. steel cover, EN 54–24 certified
Suitable for: installation in the ceilings and walls, evacuation system
up to 4 zones, 8 + 1 slots for D-class amplifiers 60 – 500 W, 42 Ah battery included, routing messages, microphones and consoles for evacuation and regular announcement, support for A / B redundancy, phase manual and automatic evacuation, 16× EPS connection, USB, SD, LAN, RS232, 12× AUX inputs, music channel selection on local controllers with LCD, high-efficiency class D amplifier in a modular concept, backup of amplifiers and power supply, monitoring, supervision and measurement, sw. control on the LCD display or via computer, certified to EN 54–4, EN 54–1
Suitable for: smaller voice alarm system including background music and user announcement, sounding of interior and exterior, stores, hotels, schools, administration
up to 8 zones, 8 + 1 slots for D-class amplifiers 60 – 500 W, 42 Ah battery included, routing messages, microphones and consoles for evacuation and regular announcement, support for A / B redundancy, phase manual and automatic evacuation, 16× EPS connection, USB, SD, LAN, RS232, 12× AUX inputs, music channel selection on local controllers with LCD, high-efficiency class D amplifier in a modular concept, backup of amplifiers and power supply, monitoring, supervision and measurement, sw. control on the LCD display or via computer, certified to EN 54–4, EN 54–16
Suitable for: smaller voice alarm system including background music and user announcement, sounding of interior and exterior, stores, hotels, schools, administration
up to 128 zones, support for A / B redundancy, routing messages, microphones and consoles for evacuation and regular announcement, phase manual and automatic evacuation, 16× EPS connection, USB, SD, LAN, RS232, 12× AUX inputs, music channel selection on local controllers with LCD, high-efficiency class D amplifier in a modular concept, backup of amplifiers and power supply, monitoring, supervision and measurement, sw. control on the LCD display or via computer, certified to EN 54–4, EN 54–16
Suitable for: voice alarm system including background music and user announcement, sounding of interior and exterior, stores, hotels, schools, administration
evacuation microphone, monitoring, test, automatic, evak. sampler, for the installation in JPA 1240B, ZA 6480, ZA 6240
Suitable for: basic solutions evacuation through amplifier central
emergency microphone, sampler, siren, monitoring, measuring, compressor and high intelligibility
Suitable for: small evacuation systems, as dedicated place of emergency announcements, connection to MA 412
week and day calendar, sampler with 8 messages (8× 1 min), local and remote control, evacuation steering, FAS connection
Suitable for: installation to the amplifier central, planing and playing annoucements, offices, shops, schools
podhledový reproduktor evakuační
Evakuační rozhlas malý (EN verze)
evakuační rozhlas
Současná praxe výběru ozvučení v hotelích a restauracích je taková, že se na ni vždy zapomíná a přitom je tak důležitá…
Ozvučení prodejen můžeme řešit dvojím způsobem, který závisí na tom, zda ozvučení má být hlasité, nebo…
Ozvučení supermarketu nebo výrobního podniku má své dva základní rysy – obvykle 2 až 6 zón a vždy jednu nebo dvě rozlehlé zóny.
Ozvučení administrativních prostor sebou nese potřebu ozvučovat několik místností, obvykle kanceláří a několik dalších prostor vč. výroby a skladů.
Ozvučení soudní síně má svá specifika. Jedná se především o požadavek na nahrávání a na velký počet mikrofonů.
Ozvučení obecním rozhlasem může probíhat prakticky dvěma způsoby. Buďto se systém buduje odznova, nebo…
Certifikace podle: (ČSN) EN 54–4:2008 (ČSN) EN 54–16:2008 EN a FR jazyk.
Abychom předešli nedorozuměním, vícepracím a vícemateriálu, sami si otázky zodpovězte, nebo nejlépe je společně zkonzultujte s uživatelem.
Nevíte, podle čeho vybírat reproduktory a reprosoustavy pro plošné ozvučení? V tomto článku poukážeme na 13 základních problémů.
Dalo by se napsat rozhlasová ústředna a Rozhlasová Ústředna. Ano, tak veliký rozdíl může mezi nimi být a k neprospěchu uživatele, jsou tyto rozdíly skryty. Laik si je neuvědomuje a tak obvykle koupí, co se namane.
V následujících řádcích popisujeme dotazy, které položte svému zamýšlenému dodavateli evakuačního rozhlasu. Jeho odpovědi srovnejte s uvedenými popisy.
Chystáte se koupit zesilovač a nevíte jaký? Na co si dát pozor? Co je důležité? Jaké parametry a provedení? A jak to všechno užijete v praxi?